Car Wave Command(IT6500C) 
  Copyright©  Itech Electronics Co., Ltd.  90
Example 
CARWave:LV124:E08 1 
Query syntax 
CARWave:LV124:E08? 
Returns 
0|1 
CARWave:LV124:E08:UBMAX[:LEVel] 
This command is used to set starting voltage Ubmax of LV124 E08. 
Command syntax 
CARWave:LV124:E08:UBMAX < value > 
Arguments 
MINimum|MAXimum|NR3   
Reset Value 
0.0 
Example 
CARWave:LV124:E08:UBMAX 50 
Query syntax 
CARWave:LV124:E08:UBMAX? 
Returns 
NR3 
CARWave:LV124:E08:UBMIN[:LEVel] 
This command is used to set keeping voltage Ubmin of LV124 E08. 
Command syntax 
CARWave:LV124:E08:UBMIN < value > 
Arguments 
MINimum|MAXimum|NR3   
Reset Value 
0.0 
Example 
CARWave:LV124:E08:UBMIN 20