Load Related Command(IT6500C) 
  Copyright©  Itech Electronics Co., Ltd.  50
Chapter9 Load Related Command(IT6500C) 
Except LOAD[:STATe] command, other commands are specially for IT6500C, 
which are not suitable for IT6500D series models. 
LOAD[:STATe] 
This  command  is  used  to  set  load  state. When  the  load  of IT6500C  Series 
power supply is on, you need to select internal load or external load. Default 
load is internal load. IT6500D Series power supply only has internal load. This 
command is used to turn on and off load function state. 
Command syntax 
LOAD[:STATe] <bool> 
Arguments 
0|1|OFF|ON 
Reset Value 
OFF 
Example 
LOAD 0 
Query syntax 
LOAD[:STATe]? 
Returns 
0|1 
LOAD:SELection 
This  command  is  used  to  select  internal  load  or  external  load,  which  is 
applicable for IT6500C Series power supply. 
Command syntax 
LOAD:SELection <INTernal|EXTernal> 
Arguments 
INTernal|EXTernal 
Reset Value 
INTernal 
Example 
LOAD:SELection INT