Input Measuring Commands 
  Copyright©  Itech Electronics Co., Ltd.  26
Chapter6 Input Measuring Commands 
MEASure[:SCALar]:VOLTage[:DC]?   
This command is used to enquire the actual output voltage. 
Command syntax 
MEASure[:SCALar]:VOLTage[:DC]? 
Arguments 
None 
Returns 
〈NRf〉 
Unit 
V 
Example 
MEAS:VOLT? 
FETCh[:SCALar]:VOLTage[:DC]? 
This command is used to fetch the DC voltage value in buffer.   
Command syntax 
FETCh[:SCALar]:VOLTage[:DC]? 
Returns 
<NRf> 
Unit 
V 
MEASure[:SCALar]:CURRent[:DC]? 
This command is used to enquire the latest DC current value. 
Command syntax 
MEASure[:SCALar]:CURRent[:DC]? 
Arguments 
None 
Returns 
<NRf>