UFD Applicator, Manual 40-43, Rev. 6.16 Page 109
Section 4, 24 VDC MAC solenoid valve, 4 way, 1/4 NPT, PN 112496
Description
Piloted spool valve (internally piloted), 4-way, 1/4 NPT ports, with non-locking recessed
manual operator.
Connections
Port 1
Inlet
Port 2
Close side of module
Port 3
Open side of module
Port 4
Exhaust
Port 5
Exhaust
Typical Setup
Apply full air pressure (80-90 psi / 5.5-6.2 bar) to Port 1 of solenoid valve. Use air control
kit PN 100055, configured as shown below.
Schematic:
PN 100055 Air Control Kit configured for use
with dual pressure solenoid valve.
Solenoid valve supplied with Applicator.