5.11 Maintenance plan
CAUTION
Heed all security advices given in Chapter 5.1.
Use only original parts from ITW Dynatec, otherwise ITW Dynatec’s warranty is void!
Please use only the indicated lubricants and keep the prescribed maintenance
intervals. Consider in addition the enclosed regulations of manufactures (if
applicable).
Punctual and conscientious maintenance of the unit secures not only a trouble free
function, but prevents also for expensive repair costs.
After maintenance work, remove all materials and tools used during the repair or
maintenance from the workspace of the unit.
Place a heat-resistant catchment container/underlay under the components. Hot
adhesive may come out.
Use only lint-free cleaning cloth and suitable cleaner for cleaning! Do not damage
surfaces! Do not scratch above them with sharp-edged tools, otherwise the
components will get leaky and inoperable!
Maintenance plan:
Operating time/
frequency
Inspection point / maintenance notes
Continuous
Remove dropped out adhesive and scrap adhesive and search for the cause
of that, eliminate the cause.
Once a day
Clean the Applicator and components from dirt.
Wipe the Applicator clean of adhesive with a clean cloth while still hot at the
end of each shift.
Once a week
Check filters for clogging and replace if necessary.
Check modules on Applicator if leaky and replace if necessary.
Check weep holes on modules if adhesive is leaking and replace seal
cartridge or module if necessary.
Check nozzles for wearing or clogging and clean or replace if necessary, or
re-adjust stroke limiter.
Check adhesive supply hose connection and tighten if loose.
Check air supply connections for leaks and tighten if loose or replace if
necessary.
Check the solenoid valves for proper function and replace it if necessary.
Every 3 months
Due to temperature differences a loosening of threads (threaded
connections) is possible. Check all parts with threads, all screw fittings and
fasteners for tightness and tighten them if necessary.
Once a year
Clean the Applicator.
Complete check-up for wearing.
Every two years
Complete maintenance.