EasyManua.ls Logo

ITW Dynatec DynaFiber UFD - Page 42

Default Icon
114 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ITW Dynatec
Chapter 5
Maintenance and Repair Notes
Page 42 UFD Applicator, Manual 40-43, Rev. 6.16
8. Separate the nozzle from its front and rear mounting plates.
9. Soak the nozzle plates in solvent. If necessary, use a non-metallic brush to remove
any foreign material, being careful not to damage any of the nozzle’s orifices. Be sure
to remove all residue before re-assembling.
10. Mount the nozzle in reverse order and attach it to the module with a torque of 20-25
in./lbs (2.3-2.8 Nm).
After finishing the maintenance or repair works:
Remove all materials and tools used during the repair or maintenance from the
workspace of the unit.
Connect the voltage supply and the compressed air supply. Heat the unit up. Wait until
all temperatures are within the tolerances and the adhesive in the tank is molten
completely.
Continue production.