EasyManua.ls Logo

IVT Greenline HC 22 - Factory Settings: Safety and Alarms; Safety Functions Default Settings

IVT Greenline HC 22
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Factory settings
6 720 645 504 (2011/04) en
101
Safety functions Factory setting
Access
level
Setting collector circuit in T10 Lowest permitted temperature E21.T10 -10,0 °C
4,0 °C Groundwater
1
Lowest permitted temperature E22.T10
-10,0 °C
4,0 °C Groundwater
1
Hysteresis alarm reset
1,0K 1
Number of warnings before alarm
11
Setting collector circuit out T11 Lowest permitted temperature E21.T11 -10,0 °C
2,0 °C Groundwater
1
Lowest permitted temperature E22.T11
-10,0 °C
2,0 °C Groundwater
1
Hysteresis alarm reset
1,0K 1
Number of warnings before alarm
11
Tab. 194 Factory settings Safety functions
General Factory setting
Access
level
Set date 0
Set time 0
Summer/winter time Automatic 0
Display backlight intensity 100% 0
Language 0
Country (Start-up) 1
Tab. 195 Factory settings General
Alarms
Factory
setting
Access
level
Alarm indication Alarm buzzer signal Interval
Blocking time
2s
Off
0
0
Alarm indication control unit
Block alarm buzzer No 0
Alarm indication room sensor
Block alarm buzzer
Block alarm indicator lamp
Yes
Yes
0
0
General alarm level Alarms and warnings No 1
Tab. 196 Factory settings Alarm

Table of Contents

Related product manuals