6 720 645 504 (2011/04) en
82
Hot water electric heater
> Acknowledge hot water additional heat
B Indicate Yes in all system solutions Chapter 8.2).
In system solution 8.2.3, there is no physical electric
additional heat in the hot water tanks but the mixed
additional heat provides hot water, extra hot water
and hot water peak. In the event of No, the Extra hot
water and Hot water peak menus are not displayed
and this is why Yes should be selected.
> Temperature change
B Set how much higher the T3 start temperature should
be when hot water is produced with the hot water
electric heater.
When the compressor produces hot water, the
temperature in the heater becomes higher. This is
compensated with this setting.
> Hysteresis
B Set hysteresis for the hot water production.
Additional heat program
This function can be used to set the times between
which additional heat mode is blocked.
> Activate program
> View/edit active program
The menu is only shown if a program is chosen.
The program for additional heat is set in the same way
as Room temperature program( Chapter 16.1.2).
> Outdoor temperature limit for deactivation of time
control
The menu is only shown if a program is chosen.
B Set a suitable temperature for deactivation of time
control. -26 °C = function Off.
If T2 is over set Outdoor temperature limit for
deactivation of time control for 15 minutes, or if
Outdoor temperature limit for deactivation of time
control is set to Off, the additional heat will be blocked
by time control as long as Additional heat program is
activated.
If T2 is under set Outdoor temperature limit for
deactivation of time control or if Additional heat
program is deactivated the additional heat will not be
blocked by time control.
Hot water electric heater is required to be
able to use the functions for Extra hot water
and Hot water peak.
Factory setting No
Alternative Yes/No
Tab. 167 Additional electric heat, hot water
The settings below are displayed only if the
additional electric heat for hot water has
been acknowledged in Start-up or here.
Factory setting 5K
Lowest value -10K
Highest value 10K
Tab. 168 Temperature change
Factory setting 2.0K
Lowest value 1.0K
Highest value 10.0K
Tab. 169 Hysteresis, hot water
Factory setting No
Alternative No/Yes
Tab. 170 Activate additional heat program
Factory setting -26 °C (Off)
Lowest value -26 °C
Highest value 20 °C
Tab. 171 Outdoor temperature limit time control