2.1.2.3 DURESS ACCESS CONTROL
This function provides unsetting of the system in a special mode. The system seemingly unsets, however
it triggers a silent panic alarm, which is then reported to selected users (including ARC).
Unsetting under duress is executed by adding 1 to the last number in a valid code.
Example for a code with the prefix:
Valid code: 2*9999 Code for unsetting under duress: 2*9990
Example for a code without the prefix:
Valid code: 9999 Code for unsetting under duress: 9990
2.1.2.4 PARTIAL ALARM SETTING
The system can also be configured to be partially set which allows guarding only by certain detectors
in a section.
Example: At night, it is possible to set the door and window detectors only, while motion detectors inside
a house do not react to anything.
To fully set the premises in which partial setting is enabled, the button to set the system has to be pressed
twice. After the button is pressed once it flashes yellow, when it is pressed a second time it flashes red.
If the system is partially set – indicated by a continuous yellow light – the entire system can be fully set
by authorization and pressing the yellow button. Once the button is pressed, the system will be fully set and
the button turns red.
2.1.2.5 TERMINATING A TRIGGERED ALARM
1. Authorize yourself using
the keypad (enter a code or hold
a card or a tag up to the reader).
The green backlit indication button
will start flashing.
2. Press the right segment button
of the selected section.
3. The command is executed,
and the segment button turns
yellow to indicate a partially set
section.
2. OPERATING THE JABLOTRON 100
+
SYSTEM
1. Authorize yourself
using the keypad (enter
a code, hold a tag
up to the reader).
2. Press the left
segment button
of the section where
the alarm has been
triggered.
3. Unsetting is finished
and sirens are silenced.
The green flashing
button indicates
unsetting of the parti-
cular section. The red
flashing light indicates
alarm memory.
4. Authorize yourself
and press the green
button again to cancel
the alarm memory
indication.
5. The segment indica-
tes the unset section
with a continuously lit
up green button.

Table of Contents

Other manuals for jablotron 100+

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the jablotron 100+ and is the answer not in the manual?

jablotron 100+ Specifications

General IconGeneral
SMS reports from the control panelYes
Voice reports from the control panelYes
System TypeWireless/Hybrid
Control PanelJA-101K
CommunicationGSM
Backup BatteryYes
Mobile AppYes
CertificationEN 50131 Grade 2
Remote accessYes, via mobile app or web interface
Power Supply230V AC
Remote ControlYes
InstallationProfessional installation recommended

Related product manuals