21
a Select the desired PG using arrows → ENTER.
a Pressing ENTER repeatedly will change the PG statuses (active PG is shown by a PG number
in a rectangle filled with black colour .
a Press ESC to exit the menu.
2.3.6.4 REMOTE CONTROL
By pressing an assigned button of a remote control. Bi-directional remote controls confirm activation
of PG outputs with an LED indicator.
2.3.6.5 MyJABLOTRON SMARTPHONE APP
By tapping on ON/OFF in the Automation (PG) tab.
2.3.6.6 MyJABLOTRON WEB INTERFACE
By clicking on ON/OFF in the Automation (PG) tab.
2.3.6.7 DIALLING-IN
Each telephone number stored in the system (one user can have one telephone number) can control one PG
just by dialling-in (i.e. without establishing a call). Dialling-in consists of dialling the phone number of the SIM card
used in the security system and hanging up before the system answers the call. By default, the system will answer
the call after the third ring (approximately 15 seconds).
2.2.6.8 SMS MESSAGE
Sending an SMS can switch on/off a particular PG. Authorization is/is not demanded based on the system
configuration.
Example: CODE_CONFIGURED TEXT
3.1 BLOCKING USERS
Any user can be temporarily blocked (e.g. when a user loses a card/tag or his access code is revealed).
When user’s access is blocked their ID code or card/tag will no longer be accepted by the system. The users
will also not receive any SMS alerts or voice reports to their phone.
Only the system administrator or service technician can block a user. One method of taking away access
rights is by choosing Settings / Users / User / Bypass and selecting “Yes” on the LCD keypad. Another option
is to locally or remotely block a user through the J-Link software by clicking on the user in the Settings / Users /
User blocking column.
A blocked (disabled) user will be marked with a red circle until the blocking is cancelled.
3.2 BLOCKING DETECTORS
A detector can be temporarily blocked in a similar way a user can be disabled. A detector is blocked when
its activation is temporarily not desirable (for example a motion detector in a room with a pet or disable a siren
sounding). The system still performs diagnostics of tamper contacts and sends service events however the alarm
function is deactivated.
Only the system administrator or service technician can block a detector. It can be achieved by choosing
Settings / Devices / Bypass and selecting Yes on the LCD keypad. Another option is to use the J-Link software
by clicking on the detector in the Settings / Diagnostics / Disabled column. A blocked detector is marked
with a yellow circle until it is turned back on using the same procedure. A device can be also blocked from
MyJABLOTRON smartphone app.
2. OPERATING THE JABLOTRON 100
+
SYSTEM
3. BLOCKING/DISABLING IN THE SYSTEM