17
2.2.1.6 SECTION CONTROL BY AUTHORIZATION
The service technician can configure the control panel to be controlled just by authorization. This way
the status of all sections can change by authorization on a keypad (by typing an access code or using
an RFID chip).
2.2.1.7 SECTION CONTROL FROM THE KEYPAD’S MENU
Control from the keypad menu:
o Authorize yourself using a valid code or an RFID chip
o Enter the menu by pressing ENTER
o Section Control ENTER
o Select the desired section using arrows
o Pressing ENTER repeatedly will change between section statuses
(partially set / set / unset)
Partial setting:
Fully set:
o Press ESC to exit the menu.
2.2.2 OPERATING THE SYSTEM WITH A KEYFOB
Keyfobs must be enrolled into the system by the installer. The keyfob can be linked to specific users,
which will prevent SMS text message notification to the user who is interacting with the system at the moment
(if notification parameters are set up in this way). The keyfob can provide either bi-directional communication,
confirming the execution of a command with a coloured indicator light, or one-way without any confirmation.
Keyfobs control and indicate battery status and are equipped with optical and acoustic indication.
Bi-directional keyfob
The button functions are differentiated by lock icons. The closed lock icon sets
programmed sections; the opened lock icon unsets them. Correct command
execution is confirmed by an LED light; unsetting – green, setting – red.
A communication fault (out of the control panel’s range) is indicated by a yellow
LED light flashing once. The buttons with symbols of full and empty circles can
control another section. Buttons of the keyfob can also be configured to control
PG outputs in different modes: the first button switches on /
the second switches off, each button can have an individual function when
impulse or change functions are used. For more functions, it is possible to press
two buttons at the same time. This way a 4-button keyfob can have
up to 6 individual functions or one PG status output (e.g. turn the lights on and off),
alternatively two PG outputs (e.g. a garage door and door lock.
If the system is configured to Set after confirmation the detector will indicate unsuccessful setting with
a green LED light if a device is triggered. It is necessary to confirm setting by pressing the lock button
again. A set section will be confirmed by a red LED light.
The keyfob buttons can be blocked to prevent accidental pressing. A command will be sent out when
a button is pressed repeatedly.
A low battery is indicated acoustically (with 3 beeps) and optically with a yellow flashing LED after
pressing a button.