7. TECHNICAL SPECIFICATIONS
PARAMETER JA-103K JA-107K
Control panel power supply ~ 110–230 V / 50–60 Hz,
max. 0.28 A with fuse F1.6 A/250 V
Protection class II
~ 110–230 V / 50–60 Hz,
max. 0.85 A with fuse F1.6 A/250 V
Protection class II
Back-up battery 12 V; 2.6 Ah (lead gel) 12 V; 7 to 18 Ah (lead gel)
Maximum battery charging time 72 h
BUS voltage (red - black) 12,0 až 13,8V
Maximum continuous current
consumption from the control
panel
1000 mA 2000 mA permanent
3000 mA for 60 minutes
(max. 2000 mA for one BUS)
Max. continuous current con-
sumption for back-up 12 hours
Without GSM com-
municator
LAN – OFF
115 mA
LAN – ON
88 mA
Valid for 18 Ah back-up battery
Without GSM
communicator
LAN – OFF
1135 mA
LAN – ON
1107 mA
With GSM commu-
nicator
LAN – OFF
80 mA
LAN – ON
53 mA
With GSM
communicator
LAN – OFF
1100 mA
LAN – ON
1072 mA
Maximum number of devices 50 230
LAN communicator ETHERNET INTERFACE, 10/100BASE-T
Dimensions 268 x 225 x 83 mm 357 x 297 x 105 mm
Weight with/without AKU 1844 g/970 g 7027 g/1809 g
Reaction to invalid code entry Alarm after 10 wrong code entries
Event memory Approx. 7 million latest events, including date and time
Power supply unit Type A (according to EN 50131-6)
GSM communicator 850 / 900 / 1800 / 1900 MHz
GSM communicator 3G 850 / 900 / 1800 / 1900 / 2100 MHz
Classification Security grade 2 / Environmental class II (according to EN 50131-1)
Operational environment Indoor general
Operational temperature range -10 °C to +40 °C
Average operational humidity 75 % RH, non-condensing
Complies with EN 50131-1 ed. 2+A1+A2, EN 50131-3, EN 50131-5-3+A1,
EN 50131-6 ed. 2+A1, EN 50131-10, EN 50136-1, EN 50136-2, EN 50581
Radio operating frequency (with
the JA 11xR module)
868.1 MHz, JABLOTRON protocol
Radio emissions ETSI EN 300 220-1,-2 (module R), ETSI EN 301 419-1, ETSI EN 301 511 (GSM)
EMC EN 50130-4 ed. 2+A1, EN 55032 ed. 2, ETSI EN 301 489-7
Safety conformity EN 62368-1+A11
Operational conditions ERC REC 70-03
Certification body Trezor Test s.r.o. (no. 3025)
Caller identification (CLIP) ETSI EN 300 089
JABLOTRON ALARMS a.s. hereby declares that the control panels JA-103K a JA-107K are in a compliance with the
relevant European Union harmonisation legislation: Directives No: 2014/53/EU, 2014/35/EU, 2014/30/EU, 2011/65/EU,
when used as intended. The original of the conformity assessment can be found www.jablotron.com – Downloads section.
Note: Although these products do not contain any harmful materials we suggest you return these products to the dealer
or directly to the producer after use.

Table of Contents

Other manuals for jablotron 100+

Related product manuals