5-82
5
MAINTENANCE
ARBUS 400Main filter
Pressure regulator (VAR)
Disassemble the pressure regulator ever y
100 working hours.
Check for wear on the valve seat (A) and
patches (B). Replace the parts if necessary.
Nozzle cleaning intervals depend on the
quality of the water and the type of agro-
chemical used.
Clean the filters whenever necessary or ev-
ery time the sprayer is filled.
The main filter is assembled according to
the illustration beside: valve (A), filtering ele-
ments (B), ring (C) and filter cap (D).
A
B
D B C A