MAINTENANCE
ARBUS 400 Winter storage
Procedures:
Drain the reservoir (A) thoroughly, lea-
ving the supply valve lever in the inter-
mediate position.
Disconnect the chemical hose (B) from
the pump (C) (hose connecting the pump
to the compensation chamber).
Run the machine for approximately 30
seconds with the tractor engine speed
between intermediate and low.
ATTENTION!
In regions where the temperature during wintertime drops to 0º°C or below, some
procedures are required to prevent damages, particularly to the chemical pump
owing to the accumulation of water inside the pump.
OBSERVATION:
Do not operate the machine
longer than the recommended
time in order not to put pump
components at risk.
Thereafter, install the components again
on their due places.
Repeat this operation at the end of every
work day, during the wintertime period,
and you will certainly prevent troubles in
the next applications.