23
XOperation of the ClearRay™ system is automatic and is de-
pendent upon activation of the circulation pump .
QHydromassage activation
XPress the key once to activate the pump: the relative LED
will light up.
Press the key a second time, the pump will turn o (LED o).
NOTES
If the pump is activated via the button, it will automatically shut
o after 20 minutes unless turned o earlier by the user.
QUnderwater spotlight (multicoloured light)
XPress the key
to activate the spotlight located on the wall
of the tub (the LED comes on).
XThe spotlight will stay on for three hours, but it can be turned
o before that by pressing the key again. Refer to the user’s man-
ual for the operation of the various sequences of colours.
Abnormal operating conditions
- alarm signals -
Alarms are indicated on the display, with the corresponding error code.
You will continue to see the code if the alarm condition persists.
XSignals on display
- possible solution
XLL
the level sensor (where present) identies a low water level. The
term “LL” will appear on the display.
- Rell the water level.
XHIExcessive water temperature
DO NOT ENTER THE WATER
The water temperature has reached or exceeded 44 °C . It is not pos-
sible to activate any function.
- If present, remove cover from spa.
- If the excessive temperature increase is due to sunlight, add
cold water to the spa.
When the temperature has dropped to below 43 °C, the spa should
re-activate automatically. If it does not, disconnect the power sup-
ply and contact an authorized Jacuzzi ® service centre.
XFrWater temperature is too low.
The tub water temperature has fallen below 9 °C. However, all func-
tions remain active.
- Activate the heater.
When the temperature exceeds 10 °C, the error message disappears.
XrPFDefective temperature probe
DO NOT ENTER THE WATER
It is not possible to activate any function.
- Check that the temperature probe is working, or replace it.
4
pump
spotlight
viewing and adjusting temperature,
parameters, functions
Temperature adjustment LED
heater LED
ltering LED
Spotlight operation LED
Pump operation LED

Table of Contents

Other manuals for Jacuzzi Flow

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jacuzzi Flow and is the answer not in the manual?

Jacuzzi Flow Specifications

General IconGeneral
BrandJacuzzi
ModelFlow
CategoryHot Tub
LanguageEnglish

Related product manuals