4-5-2 Factory Initializations
1) Turn on the power while pressing key SMPL and G/N/SET; the scale displays
F.INIT(SET 00). Press G/N/SET to show F.INIT?, and hold key G/N and G/N/SET again
to show INIT--- and OK and back to F.INIT.
2) Press key ZERO/ ESC to return to weighing mode.
4-6 Unit setting menu
1) Factory default unit setting
Turn on the power while pressing key SMPL and G/N/SET; the scale will show
F.INIT(SET 00). And use key MR or TARE to choose parameter F.UNIT(SET 03). Use key
G/N/SET to enter unit switch screen, and use SMPL to choose the unit between kg, g, lb,
lb-oz, 市斤, 台斤, 台斤-台两, 港斤, 港斤-港两, pcs, use MR or TARE to choose ON or
OFF. Press M+/SAVE to save the setting and back to F.UNIT. Press key ZERO/ESC to
return to weighing mode.
Note: only the unit set ON could be used by user.
2) unit setting by user
Turn on the power while pressing key G/N/SET; the scale displays CHECK(SET 00)., and
use MR or TARE to choose the parameter UNIT(SET 03).. Use G/N/SET to show the
weight’s unit and unit weight unit ‘s, Press SMPL to choose the unit needed, such as ①KG、
G、、 ② G、G、、③ LB、LB、、④ KG、KG、、, press M+/SAVE to save setting, press
ZERO/ESC to return UNIT flashs, and press ZERO/ESC to return to weighing mode.
4-7 In System Programming (ISP)
Press and hold key SMPL and G/N/SET while powering on the scale. The window
displays “F.INIT” (SET 00), and use MR or TARE to choose the parameter ISP(SET 01),
use G/N/SET to show ISP?. Hold on the key G/N and G/N/SET and show ISP…..and
enter ISP mode.