JAKA Zu
®
7 - V1.1 30
Bolted tightening torque table
SUS bolt with hexagon hole
The tightening torques will vary depending on the type of base metal or bolt. When not specified, please
follow the tightening torques above.
Inspection/processin
g method
Whether there is
splashes, dust, etc.
Visual confirmation,
cleaning
Whether there is
dirt or blockage
Visual confirmation,
cleaning,
replacement
• Confirm whether
there is any
damage or
fragmentation
• Confirm whether
the connectors are
loosed.
Visual confirmation,
tightening. Replace
the cable when it is
obviously damaged.
(P.S.) Use a soft cloth to remove dusts when cleaning. Do not blow off dust with equipment such as air
blowers. Wind pressure will cause the dusts to enter the inside of the fan and the blades rotate at a speed
exceeding the rated speed, which may cause the fan to malfunction or affect its life. Only use the vacuum
cleaner on the blade section. Do not vacuum the rotating part or the main body, which can cause the fan to
malfunction or reduction of the fan’s service life.