The following table lists some of the most common problems when running the heater. Most problems occur when the
heater is started for the rst time after installation or at spring start-up.
Symptom Possible Cause Remedy
Pump not operating No power.
Pump defective.
Incorrectly wired.
Time clock settings not synchronized with
actual time.
Check circuit breakers and power source.
Replace the pump.
Recheck wiring.
Check time clock setting.
Unstable combustion-
(1) heater turns off and on
(2) heater ignites slowly
(3)ameliftsandgoesout
(4)shortyellowstreakedame
Wrong gas.
Lean fuel/air mixture— low supply
pressure.
Lean fuel/air mixture— too much
combustion air.
Rich fuel/air mixture— high manifold
pressure.
Rich fuel/air mixture— too little combustion
air.
Make sure the gas supply matches the gas type
indicated on the rating plate.
Correct gas supply pressure to 4.0 “ W.C.
Increase offset gas pressure. Rotate adjustment
screw clockwise.
Correct gas supply pressure to 4.0 “ W.C.
Decrease offset gas pressure. Rotate adjustment
screw counter-clockwise.
Check offset pressure is set to —0.2” W.C. If this is
set properly, connect manometer to blower throat and
gas valve port to obtain differential. Make sure the
differentialvaluefallswithinthespeciedrangefor
the heater size (see Table TBD).
Not enough heat
(1) heater is slow to heat up
(2) heater not maintaining set
temperature
Incorrect gas valve offset pressure.
Heater size inadequate.
Filter pump not running long enough.
Gas meter too small.
Gas line from meter to heater too small.
Correct gas supply pressure to 4.0 “ W.C.
Replace with heater of higher input.
Check blower inlet grill for obstruction.
Heater pounding or knocking Waterowthroughheatertoolow.
Failed Thermal Regulating Valve (TRV).
Look for obstruction or closed valve in system.
Check for damaged internal bypass.
Variable speed pump set too low
Dirtylterorbaskets
Low temperature rise Low water temperature.
Heater plumbed backwards.
Heater is condensing. Flue product moisture will
condense at the start-up until the heater water
temperature reaches the normal operating conditions.
Faulty or broken Thermal Flow Regulator.
Correct the plumbing.
TRV failure.
Igniterlightsbutdoesnotre Gas valve is not ON.
Air in gas line.
Gas valve failed.
No power to gas valve.
Low gas pressure.
High burner throat pressure.
Flip the switch to “on” position.
Cycle ignition sequence until air is out of the gas line.
Replace gas valve.
Check controls for proper operation.
Check supply pressure.