1. Remove the presser foot, needle plate and bobbin
holder.
2. Turn the power switch on and select the stitch No. 2.
3. Press ADJUST key and set the zigzag width to 0,
then turn the power switch off.
4. Turn the handwheel to raise needle bar (1) from its low-
est position until the tip of the rotary hook meets the
right side of the needle (2).
5. Open the face cover and loosen screw (A) as shown.
6. Move the needle bar (1) up or down to adjust the needle
bar height.
7. Tighten the screw (A). Be sure that the groove (3) on
the needle bar is facing exactly forward.
8. Close the face cover.
9. Reattach the bobbin holder, needle plate and presser
foot.
[Alternative way of adjustment]
1. Raise the needle to its highest position.
2. In this condition, the distance between the tip of needle
and the surface of the needle plate should be 16.3 mm.
(A)
Adjusting Needle Bar Height
The standard distance between the upper edge of the needle eye and the tip of the rotary
hook should be in the range of 1.6 - 2.0 mm when the rotary hook meets the right side of the
needle as the needle travels up from its lowest position.
(1)
(2)
(3)
Needle #14
Rotary hook race
Top of needle eye
Surface of hook race
1.6 - 2.0 mm
19
1.8 mm
(Gauge 860G001)
16.3 mm
(Gauge 860G001)
www.promelectroavtomat.ru