16.5 mm
4.3 - 5.3 mm (X)
(A)
(B)
(Y)
Adjusting X and Y Sensors
1. Turn the power switch on to set to the initial setting.
2. Turn the power switch off and remove the base
unit.
3. Remove the Y carriage cover (1), X carriage cover
(2), X carriage cap (3) and embroidery base covers
(4) and (5).
4. Loosen the screw (A) to adjust dimension (Y) to be
between 16 mm and 17 mm by moving the Y sensor
attaching plate (6).
5. Loosen the screw (B) to adjust dimension (X) to be
between 4.3 mm and 5.3 mm by moving the X sensor
attaching plate (7).
7. Attach the Y carriage cover (1), X carriage cover (2),
X carriage cap (3) and embroidery base covers (4)
and (5).
8. Attach the base.
(6)
(1)
(2)
(3)
(4)
(5)
(7)
41
(Gauge 860G001)
17 mm
16 mm
5.3 mm
4.3 mm