AAA-055-00138 Rev. 1/14/15
Jaylor Owner Manual - 47 - Mini Mixer Models
- Auger stops rotating
during mixing.
- Auger jammed.
- Clear packed material
and resume mixing.
- Un-lubricated auger
support bushing.
- Lubricate auger support
bushing.
digging into drum floor.
- Adjust auger height.
- Improper use of safety
switches (CE units).
- If unloading door is open,
foot safety switch must
be depressed or auger
- Auger rotates slowly
during mixing.
- Hydraulic oil too hot.
- Allow system to cool and
resume mixing.
- Remove debris from all
hydraulic system
components.
- Make sure hydraulic oil
cooler fan is operating
(A100 models). Replace
- Difficult to steer (self-
propelled model).
- Un-lubricated steering
system.
- Lubricate steering
bearings, roller chain,
and gears/u-joint (within
the steering assembly).
bearing(s) in steering
- Replace sealed flange
bearing(s).
- Low air pressure in tire.
- Increase air pressure to
maximum recommended
- Steering chain loose.
- Adjust tension of steering
chain (see section ‘33.0
Steering Chain
- Difficult to stop (self-
propelled model).
- Un-lubricated
speed/direction control
pedal.
- Lubricate the pedal
bushings under the
operator’s platform and
clear any packed
material around the
pedals.
- Electronic controls not
working.
- No charge in battery
- Charge battery or
replace if necessary.
- Faulty wiring/blown fuse.
- Check wiring for damage
and check for blown
fuses. Repair/replace
- No current through starter
motor when attempting
to start the engine.
- Improper use of safety
switches (CE units).
switch is in the ‘off’
position and parking