Hopper Tank
A hopper tank is recommended, between the main fuel tank and the engine. JetCat USA
highly recommends the BVM UAT for the hopper tank!
Always use the filter between the fuel pump and the solenoid valve as shown in the
diagram. This is true even when using the BVM UAT! The pump will emit small
particles that can block the solenoid valve from completely closing!
Prime the pump and system.
To prime the fuel pump and fuel lines (or for fuel pump test purposes), it is necessary to
open the fuel shutoff valve and run the fuel pump manually. For this purpose, use the Test–
Functions Menu selection, Pump TestVolt. This test opens the fuel valve and acts as a
speed control for running the pump.
, Extremely Important:
Pump Test allows the fuel pump to operate without the turbine running. However, if the fuel
feed line is not removed from the turbine during this procedure; it will become flooded with
fuel. When this occurs, the next turbine start can become highly combustible!
Before activating the pump test mode, ALWAYS remove the fuel feed line connected
to the turbine.
Press the Change Value/Item key to run the pump. If you want to change the voltage the
pump runs at, press either the - or + while pressing the Change Value/Item key.