Fuel pump adjustment
After the turbine has ignited on propane, the starter motor further accelerates the
turbine. At approx. 5000 RPM, the fuel pump is automatically started at minimum power
by the ECU. Beginning from this first pump start voltage, the fuel flow is then slowly
increased by increasing the pump voltage.
The initial pump voltage that the pump is supplied immediately after ignition has been
factory adjusted. If the fuel pump is changed or after several turbine runs the pump is
breaking in thus delivering too much fuel at start-up causing long flames behind the
turbine exhaust, it might be necessary to readjust the pump start voltage.
For adjustment of the pump start voltage, the ECU incorporates a special adjustment
function, which can be accessed as follows:
Interrupt fuel supply to the turbine. If the fuel supply to the turbine is not disconnected /
interrupted the turbine can be “filled” with fuel during the following adjustment
procedure!!! Æ Danger of a “Hot Start”
Switch off ECU and plug in GSU (RC transmitter is not being used)
Press
and hold the key “Change Value/Item” on the GSU and switch on the ECU
Release the “Change Value/Item” when the display of the GSU shows the following:
Pump start volt.
Uaccelr1:
By pressing the “Run” key will run the pump at the current start voltage value.
To increase the pump start voltage by one increment, press the + key.
To decrease the pump start voltage by one increment, press the - key.
The pump start voltage should now be adjusted in such a manner, that the pump just
begins to steadily turn and that the fuel is delivered in a thin fuel stream (a little bit more
than just dripping out of the tubing). To test this, press the “Run” key several times to
check that the pump starts steadily running on different pump rotor positions.
Normal values for the pump start voltage are between 0.100 and 0.325V.
Important:
At the end of the adjustment procedure press the “Manual” key to store the new setting
and resume to normal operation.
20

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JetCat SPH5 and is the answer not in the manual?

JetCat SPH5 Specifications

General IconGeneral
Engine TypeTurbine
Thrust50 N
Maintenance interval25 hours
Fuel TypeJet A1, Kerosene, Diesel
Start MethodElectric
Lubrication5% oil content in fuel