Alarm for New Target Acquired in Automatic Acquisition Zone (New Target) 
 
 
CAUTION 
In setting an automatic acquisition zone, it is necessary to 
adjust the gain, sea clutter suppression and rain clutter 
suppression to ensure that target echoes are displayed in 
the optimum conditions.    No automatic acquisition zone 
alarms will be issued for targets undetected by the radar, 
and this may cause accidents such as collisions. 
 
 
The automatic acquisition function sets a zone in a range and issues an alarm when a new target (which is 
not yet acquired) goes into this zone. 
For the setting of an automatic acquisition zone, refer to " Acquiring Target " in Section 5.2.1. 
 
 
Alarm for New Target Acquired in Automatic Acquisition Zone 
 
Status  Symbol on display  Alarm characters Alarm sound  Conditions 
New target in 
automatic 
acquisition 
zone
 
Red Blinking 
New Target 
Beep sound (pipi-pipi) 
Alarm 
acknowledgeable
 
The alarm is issued when 
a new target is acquired 
in the automatic 
acquisition zone.
 
 
Note:  When an already acquired target goes into automatic acquisition zone, the alarm message 
is not displayed and the buzzer does not sound either. 
5-47