[V]    System Alarm Log display 
 
Displays previously occurred system alarms with the dates and times 
when they occurred. 
 
The Alarm log display button (2-29P Alarm) is clicked, in the same 
way as that one. 
 
To display the occurrence alarm , press the   
  1. Display Only Occurrence    button. 
To erase the alarm logs, press the  2. All Clear  button. 
 
 
 
 
 
 
 
 
 
The current alarm is displayed at the lower right of the radar display.    For details, refer to Chapter 9. 
 
   
 
 
[VI]  System INFO 
 
Displays the current system information. 
 
  Indicator      Processor software version information 
  TXRX      Scanner software version information 
  System No.      System number 
  TX Time      Total magnetron transmitting time (Total time during which 
  radar was transmitted) 
 X-Band    
 S-Band    
  Motor Time      Total operating time (Total power-on time) 
  TXRX Total Time    Total operating time of the scanner unit (Total power-on time of 
  the antenna unit) 
  Total Time      Total operating time of the display unit (Total power-on time of 
  the display unit) 
 
 
[VII]  Magnetron Current 
 
Displays the Magnetron Current bar indicating the magnetron current to check. 
When a 48 NM range is set, the magnetron current is normal if the Magnetron Current bar reads the value 
below. 
 
JMA-5312-6/6HS 10 kW: 4-7 scale marks 
JMA-5322-7/9/6HS 25kW, JMA-5332-12 30 kW: 6-9 scale marks 
 
Note:  Displays the Magnetron Current bar instability indicating in sector blank area, but it is normal 
operating. 
For how to setting sector blank function, see Section 7.2.2. 
8-11