EasyManuals Logo

JRC JMA-922B-9XA Installation Manual

JRC JMA-922B-9XA
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #133 background imageLoading...
Page #133 background image
5-50
5.4.10.3 Output Setting of Relay Contact Signal
The output port of the relay contact signal is set.
The setting not output or the output terminal fixation can be set.
1) Open the Alarm.
2) Left-click the Relay Output.
3) Set each output relay contact signal.
The contact signal is output to the terminal set to set the name of the output terminal.
TT: Setting of terminal that outputs dangerous ship alarm. (ARPA ALR)
System: Setting of terminal that outpus system alarm. (SYS ALR)
Navigation: Setting of terminal that outpus nagivation alarm. (OP CONTACT)
CPA ACK: Setting of terminal that outpus watchman timer reset signal (WMRST OUT)
Alarm ACK: Setting of terminal that outpus alarm ACK. (ACK OUT)
5.4.10.4 Output setting of ALR sentence
Alarm information added to the ALR sentence is set.
1) Open the Alarm.
2) Left-click the ALR Output.
3) Set each output alarm.
TT Alarm: Setting that adds information on dangerous ship alarm to ALR
sentence.
System Alarm: Setting that adds information on system alarm to ALR sentence.
Navigation Alarm: Setting that adds information on navigation alarm to ALR sentence.

Table of Contents

Other manuals for JRC JMA-922B-9XA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JRC JMA-922B-9XA and is the answer not in the manual?

JRC JMA-922B-9XA Specifications

General IconGeneral
BrandJRC
ModelJMA-922B-9XA
CategoryMarine Radar
LanguageEnglish

Related product manuals