Loading...
Maintenance & Inspection
6-16
095 Controller CTRL1 memory
Detected a memory error on the
No.1 controller.
Please contact JRC or
our agency.
096 Controller CTRL2 memory
Detected a memory error on the
No.2 controller.
Please contact JRC or
our agency.
059
Data
terminal
My/OTH DTE lost
Detected a serial communication
error between controller (ID:1)
and DTE.
Note) My or OTH indicates the
relationship between that data
terminal and the controller
displaying this information.
Check the data
terminal cable
connection, or the
condition of the data
terminal.
060
Data
terminal
My/OTH DTE lost
Detected a serial communication
error between controller (ID:2)
and DTE.
Note) My or OTH indicates the
relationship between that data
terminal and the controller
displaying this information.
Check the data
terminal cable
connection, or the
condition of the data
terminal.
062
Data
terminal
My/OTH DTE
USB-IC
Detected the SPI communication
error at the USB circuit of the
data terminal connected to the
controller (ID:1).
Note) My or OTH indicates the
relationship between that data
terminal and the controller
displaying this information.
Please contact JRC or
our agency.
063
Data
terminal
My/OTH DTE
USB-IC
Detected the SPI communication
error at the USB circuit of the
data terminal connected to the
controller (ID:2).
Note) My or OTH indicates the
relationship between that data
terminal and the controller
displaying this information.
Please contact JRC or
our agency.
Also, the following Maintenance information are displayed when an error is detected just after
turning on the equipment. Please notify JRC or our agency of the details of the information.
Display Contents
Detected this controller's barcode number lost!
So, required to replace the CONTROL UNIT in it
with the new one.
Detected an error in the barcode number on the
controller.
Detected this controller's SIO error!
So, required initial set after restarting as the
maintenance mode.
Detected a communication error between the
controller and transceiver at startup.
Detected this controller's address setting error!
So, required initial set after restarting as the
maintenance mode.
Detected this controller's address error when
starting the controller.
Detected MMSI lost!
So concerned DSC functions no longer available
now.
Unregistered MMSI, or lost the MMSI.
Detected PA UNIT lost or this controller's SIO error!
So, required initial set after restarting as the
maintenance mode.
Detected malfunction of the PA unit or
communication error on the controller.
Detected TRX UNIT lost!
So, concerned all functions no longer available
now.
Detected TRX unit malfunction.