– 39 –
– 360˚
– 180˚
0˚
180˚
360˚
* When the point
before 1 stitch is
regarded as 0˚,
compensation is
possible by 360˚ (1
stitch) in front and in
the rear.
– 360˚
– 180˚
0˚
180˚
360˚
– 360˚
– 180˚
0˚
180˚
360˚
Set value
Compensation angle
Number of stitches of compensation
–
36
–
360
゜ –
1
–
1
8
–
180
゜ –
0.5
0 0
゜
0
1
8 180
゜
0.5
36 360
゜
1
3
Compensation of off-timing of solenoid for reverse feed stitching at the end of sewing (Function setting No. 53)
Off-timing of solenoid for reverse feed stitching at the start of sewing can be compensated by the unit of angle.
Adjusting range
– 36 to 36 <1 / 10˚>
!6
C
ompensation of timing of the solenoid for reverse feed stitching (Function setting No. 51 to 53)
When the normal and reverse feed stitches are not uniform under the automatic reverse feed stitching action, this
function can change the ON / OFF timing of the solenoid for back tack and compensate the timing.
1
Compensation of on-timing of solenoid for reverse feed stitching at the start of sewing (Function setting
No. 51)
On-timing of solenoid for reverse feed stitching at the start of sewing can be compensated by the unit of angle.
Adjusting range
– 36 to 36 <1 / 10˚>
2
Compensation of off-timing of solenoid for reverse feed stitching at the start of sewing (Function setting No. 52)
Off-timing of solenoid for reverse feed stitching at the start of sewing can be compensated by the unit of angle.
Adjusting range
– 36 to 36 <1 / 10˚>
Set value
Compensation angle
Number of stitches of compensation
–
36
–
360
゜ –
1
–
1
8
–
180
゜ –
0.5
0 0
゜
0
1
8 180
゜
0.5
36 360
゜
1
Set value
Compensation angle
Number of stitches of compensation
–
36
–
360
゜ –
1
–
1
8
–
180
゜ –
0.5
0 0
゜
0
1
8 180
゜
0.5
36 360
゜
1
!5
Holding time of lifting presser foot (Function setting No. 47)
Th
is function automatically lowers the presser foot when the time set with the setting No. 47 has passed after
lifting the presser foot.
When the pneumatic type presser foot lifter is selected, the holding time control of lifting presser foot is limit
-
less regardless of the set value.
Sett
ing range
10 to 600 sec <10 / sec>
4
7 6 0
5 1 1 2
5 2 1 8
5 3 1 6