EasyManua.ls Logo

JUKI DDL-8700A-7 - Pedal Sensor Installation; Power Switch Installation

JUKI DDL-8700A-7
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 4 –
1
1
2. Installing the pedal sensor
The explanation applies to the case the
pedal sensor is installed on the table for
the DDL-8700A-7.
1) Install the pedal sensor on the table
by means of mounting bolt asm.
1
supplied with the unit. At this time,
insert the nut and washer supplied
with the unit as accessories as shown
in the gure so that the control box is
securely xed.
2) After the completion of installation of
the pedal sensor on the table, place
the sewing machine head on the
table.
Spring
washer
Hexagonal
nat
1
Plain
washer
3. Installing the power switch
1) Remove screw
1
on the side face of the power
switch cover to open the power switch cover.
2)
Pass AC input cord
2
coming from the control box
through the rear face of the power switch. Bundle
the cord with cable clip band
3
to secure it.
(Caution) Do not insert the power plug into the plug receptacle.
2
3
WARNING :
• To protect against personal injury resulting from abrupt start of the sewing machine, be sure to
turn the power OFF, unplug the machine and wait for ve minutes or more before installing the
pedal sensor.
•
To prevent damage of device caused by maloperation and wrong specifications, be sure to
connect all the corresponding connectors to the specied places. (If any of the connectors is
inserted into a wrong connector, not only the device corresponding to the connector can break
but also it can start abruptly, inviting the risk of personal injury.)
•
To prevent personal injury caused by maloperation, be sure to lock the connector with lock.
• As for the details of handling respective devices, read carefully the Instruction Manuals supplied
with the devices before handling the devices.

Table of Contents