Table 43: Chassis Alarm Messages for QFX5200-32C and QFX5200-48Y
(Connued)
Component Alarm Type CLI Message Recommended Acon
Power supplies Major (red)
PEM
pem-number
Airflow not matching
Chassis Airflow
Replace the power supply with a
power supply that supports the
same airow direcon as supported
by the chassis.
PEM
pem-number
I2C Failure
Check the system log for one of the
following error messages and report
the message to customer support:
I2C Read failed for device
number
, where
number
where
number ranges from 123
through 125.
PS
number
: Transitioning from
online to offline, where power
supply
number
is 1 or 2.
PEM
pem-number
is not powered
Check the power cord connecon
and reconnect, if necessary.
PEM
pem-number
is not supported
Replace the power supply with a
supported power supply.
PEM
pem-number
Not OK
Indicates a problem with the
incoming AC power or outgoing DC
power. Report the error to customer
support.
Minor (yellow)
PEM
pem-number
Absent
Reboot the switch aer removing
one of the power supply. The
switch can connue to operate with
a single power supply.
OR
Replace the removed power supply
and reboot the switch.