Table 43: Chassis Alarm Messages for QFX5200-32C and QFX5200-48Y
(Connued)
Component Alarm Type CLI Message Recommended Acon
PEM
pem-number
Power Supply Type
Mismatch
Check whether there is a mix of AC
and DC power supplies in the same
chassis. Reboot the switch with only
AC or only DC power supplies.
PEM
pem-number
Removed
Replace the removed power supply
or reboot the switch. The switch
can connue to operate with a
single power supply.
Temperature
sensors
Major (red)
sensor-location
Temp Sensor Fail
Check the system log for the
following error message and report
the message to customer support:
Temp sensor
sensor-number
failed,
where
sensor-number
ranges from
1 through 10.
sensor-location
Temp Sensor Too Hot
Check environmental condions
and alarms on other devices. Ensure
that environmental factors (such as
hot air blowing around the
equipment) do not aect the
temperature sensor. If the condion
persists, the device might shut
down.
Minor (yellow)
sensor-location
Temp Sensor Too
Warm
Check environmental condions
and alarms on other devices. Ensure
that environmental factors (such as
hot air blowing around the
equipment) do not aect the
temperature sensor.
Roung Engine Minor (yellow)
RE
RE number
/var partition usage
is high
Clean up the system le storage
space on the switch. For more
informaon, see
Cleaning Up the
System File Storage Space
.
153