Reset the Device to Factory Defaults 39
2. Wait for one to two seconds.
After the first reset, the STATUS LED blinks green; the device is now waiting for
the second reset. The Console message now states that the device is waiting for
a second confirmation.
3. Push the reset pinhole again for four to six seconds.
The Console message verifies the second reset. The STATUS LED glows red for
one-half second and then returns to the blinking green state.
The device then resets to its original factory settings. When the device resets,
the STATUS LED glows red for one-half second and then glows green. The
Console displays device bootup messages. The system generates SNMP and
SYSLOG alerts to configured SYSLOG or SNMP trap hosts.
After the device has rebooted, the Console displays the login prompt for the
device. The STATUS LED blinks green. The login for username and password is
netscreen.
If you do not follow the complete sequence, the reset process cancels without any
configuration change and the console message states that the erasure of the
configuration is aborted. The STATUS LED returns to blinking green. If the device
did not reset, an SNMP alert is sent to confirm the failure.