144 JVL Industri Elektronik A/S - User Manual - Ethernet for MAC and MIS motors
6.2 Commissioning
14. Drag and drop the MAC00-EPx to the Network view.
15. Also add your PLC to the Network view (see also Siemens documentation for further
info).
16. Ifusingexternalswitchesthenthesemustbeaddedtoo(seeSiemensdocumenta
tionforfurtherinfo).Ifnotcontinuetothenextstep.
17. Connect the two devices, by dragging a line between the small green boxes in each
device, and it should now look like below.
Associating with the cyclic data
18. Drag the “8 registers input” and “8 registers output” from the hardware cata-
log under Other field devices / PROFINET I/O / I/O / JVL Industri Elektronik
A/S / PNS / Module / Input modules and Output modules, and drop them in the
Device overview of the MAC00-EPx. See illustration next page.