JVL Industri Elektronik A/S - User Manual - Ethernet for MAC and MIS motors 191
8.2 Commisioning
8.2.6 Quick start FSP Drive Profile and Bosch-Rexroth MLC/XLC master.
This paragraph guides you through the steps needed to run the motor with the FSP Drive
Profile.
8.2.6.1 Enabling FSP Drive / Pack Profile.
For using the FSPDrive Profile the “FSP Drive / Pack Profile” has to be enabled in the JVL
Sercos
®
module. This is factory default setting, but if not enabled already, then check the
“FSP Drive / Pack Profile” checkbox in the Sercos tab in Mactalk, and press the “Apply
and save” button. Please refer to the picture below.
For connecting MacTalk to the motor please refer to Connect to MacTalk, page 182.
8.2.6.2 Add SDDML file to IndraWorks
Start IndraWorks with an empty project.
Download the Sercos
®
SDDML file from the JVL homepage here:
http://www.jvl.dk/default.asp?Action=Details&Item=428
Install the SDDML file in IndraWorks by selecting “Device database” in the tools menu.