260 JVL Industri Elektronik A/S - User Manual - Ethernet for MAC and MIS motors
12.1 Technical Data
12.1.4 PROFINET IO for MAC or MIS - Technical specifications
Galvanic isolated, 100MBit, full duplex, 100Base-Tx, no termination necessary.
Network topology: Line, ring, tree and star possibly.
Forwarding delay: 3.25μs.
Minimum cycle time: 1ms (with MAC400-4500).
Supported Protocols
• CL-RPC – Connection less Remote Procedure Call
• DCP – Discovery and Configuration Protocol
• LLDP – Link Layer Discovery Protocol
• RTA – Real time Acyclic Protocol
• RTC – Real time Cyclic Protocol, Class 1
• SNMP – Simple Network Management Protocol
• MRP – MRP Client is supported
Max. 100 m cable between slaves.
Connectors (only applicable to MAC00-EPx):
• “PWR” (power) M12 connector 5pin male
• “I/O” M12 connector 8pin female
• “L/A IN” and “L/A OUT” (Ethernet) M12 connector 4pin D-coded female.
Supply (only applicable to MAC00-EPx):
Supply voltage (CV): 12-48VDC Nominal (absolute max. 50V)
Current rating @ 24V DC (CV): typical 150mA, max. 250mA
User I/O (only applicable to MAC00-EPx):
Digital input impedance: 4.7k
Digital input current @24V: 5.1mA
Digital output current (HW rev. Up to 1.2): 10mA
Digital output current (HW rev. from 1.3): 15mA