EasyManua.ls Logo

JVL MAC00-EC41 - Page 260

JVL MAC00-EC41
300 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
260 JVL Industri Elektronik A/S - User Manual - Ethernet for MAC and MIS motors
12.1 Technical Data
12.1.4 PROFINET IO for MAC or MIS - Technical specifications
Galvanic isolated, 100MBit, full duplex, 100Base-Tx, no termination necessary.
Network topology: Line, ring, tree and star possibly.
Forwarding delay: 3.25μs.
Minimum cycle time: 1ms (with MAC400-4500).
Supported Protocols
CL-RPC – Connection less Remote Procedure Call
DCP – Discovery and Configuration Protocol
LLDP – Link Layer Discovery Protocol
RTA – Real time Acyclic Protocol
RTC – Real time Cyclic Protocol, Class 1
SNMP – Simple Network Management Protocol
MRP – MRP Client is supported
Max. 100 m cable between slaves.
Connectors (only applicable to MAC00-EPx):
“PWR” (power) M12 connector 5pin male
“I/O” M12 connector 8pin female
“L/A IN” and “L/A OUT” (Ethernet) M12 connector 4pin D-coded female.
Supply (only applicable to MAC00-EPx):
Supply voltage (CV): 12-48VDC Nominal (absolute max. 50V)
Current rating @ 24V DC (CV): typical 150mA, max. 250mA
User I/O (only applicable to MAC00-EPx):
Digital input impedance: 4.7k
Digital input current @24V: 5.1mA
Digital output current (HW rev. Up to 1.2): 10mA
Digital output current (HW rev. from 1.3): 15mA