EasyManua.ls Logo

JVL MAC00-EC41 - Page 261

JVL MAC00-EC41
300 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
JVL Industri Elektronik A/S - User Manual - Ethernet for MAC and MIS motors 261
12.1 Technical Data
12.1.5 Modbus TCP/IP for MAC or MIS - Technical specifications
Galvanic isolated, 100MBit, full duplex, 100Base-Tx, no termination necessary.
Network topology: Line, ring, tree and star possibly.
Forwarding delay: 10-130μs.
Minimum cycle time: 2ms (with MAC400-4500).
Max. 100 m cable between slaves.
Protocol:
Function codes supported: 3, 16, 23.
Max. 124 modbus read registers per frame ( = 62, 32bit registers).
Max. 32 modbus write registers per frame (= 16, 32bit registers)
32bit support by 2x16bit registers. Only even no. of 16bit registers.
I/O mode: Server, port 502.
Connectors (only applicable to MAC00-EMx):
“PWR” (power) M12 connector 5pin male
“I/O” M12 connector 8pin female
“L/A IN” and “L/A OUT” (Ethernet) M12 connector 4pin D-coded female.
Supply (only applicable to MAC00-EMx):
Supply voltage (CV): 12-48VDC Nominal (absolute max. 50V)
Current rating @ 24V DC (CV): typical 150mA, max. 250mA
User I/O (only applicable to MAC00-EMx):
Digital input impedance: 4.7k
Digital input current @24V: 5.1mA
Digital output current (HW rev. Up to 1.2): 10mA
Digital output current (HW rev. from 1.3): 15mA
12.1.6 Sercos
®
for MAC and MIS motors - Technical specifications
Galvanic isolated, 100MBit, full duplex, 100Base-Tx, no termination necessary.
Network topology: Line and ring possibly.
Forwarding delay: <1μs.
Minimum cycle time synchronized MAC400-MAC4500: 1ms
Minimum cycle time synchronized MISxxxES / SMCxxxES : 1ms
Minimum cycle time FSP IO profile / JVL profile non-synchronized: 500μs (with
MAC400-MAC4500).
Max. jitter (synchronized): ±1μs.
Max. 100 m cable between slaves.
Maximum number of applicable Sercos® addresses 511
Supported Sercos® Communication Specification Version1.1.2
SCP Sync support yes
SCP_NRT PC support yes
S/IP support yes
Identification LED feature supported yes
Hot plug yes
Direct Cross communication no
The sequences MDT-AT-UCC and MDT-UCC-AT (only with SCP_Sync active) are sup-
ported
(continued next page)

Table of Contents