Summary of Pushbutton Programming Commands
Name Command Description of Command Authorization
Activate
Users
300 #
NNN#
‘Activate User Access Code’
NNN = specific User ID location (001 to 299)
Master, Mgr
301 #
NNN#
‘Activate Manager Access Code’
NNN = specific User ID location (001 to 299)
Master
302 #
NNN#
‘Activate Service User Access Code’
NNN = specific User ID location (001 to 299)
Master, Mgr
303 # ‘Activate M-Unit User Code’ Master, Mgr
398 # ‘Activate all User Codes’ (except Master,
Manager and M-Unit User)
Master, Mgr
399 #
P#
‘Activate / De-Activate Passage Mode’
(P = 0 or 1; 0 = disable Passage Mode;
1 = enable Passage Mode)
Master, Mgr
De-activate
Users
400 #
NNN#
‘De-Activate User Access Code’
NNN = specific User ID location (001 to 299)
Master, Mgr
401 #
NNN#
‘De-Activate Manager Access Code’
NNN = specific User ID location (001 to 299)
Master
402 #
NNN#
‘De-Activate Service User Access Code’
NNN = specific User ID location (001 to 299)
Master, Mgr
403 # ‘De-Activate M-Unit User Code’ Master, Mgr
498 # ‘De-Activate all User Codes’ (except Master,
Manager, and M-Unit User)
Master, Mgr
499 #
L#
‘Activate / De-Activate Lockout Mode’
(Master User doesn’t affect by Lockout
Mode) (L = 0 or 1; 0 = disable Lockout Mode;
1 = enable Lockout Mode)
Master
Diagnostic
500 #
1234567890*#
‘Manual diagnostic’ Master, Mgr
Communication
Startup
900 # ‘Communications startup’ Master, Mgr