7
  2.  You have up to 5 seconds to push ‘#’ and release the override key. If   
    5-second timeout is reached without pressing ‘#’, the lock continues  
    its normal operation. As soon as the ‘#’ is pressed, the lock exits the  
    current state. If timeout is reached or if any other key is pressed after  
    the ‘#’ was pressed, the lock exits the sequence and stays in access  
    state. If ‘#’ is pushed and reset button is released within 5-second 
    period, the lock goes in Reset Sequence State and the lock displays  
    the ‘Reset Sequence In Progress’ message by flashing Green and Red  
    LED alternatively once every second. 
  3.  In this state, users have a 20-second period to enter the Master Code  
    to perform a hard reset. If a bad Master Code is keyed-in, the lock exits  
    the Reset Sequence State and goes back in access state. If the correct  
    Master Code is entered within 20 seconds, the lock performs a hard  
    reset and goes back in unprogrammed state. When an incorrect Master  
    Code is entered, the Tamper Count decrements. After 4 unsuccessful  
    attempts to Reset the lock with a bad Master code, the lock goes in  
    the Tamper Shutdown state for 30 seconds. It will resume normal  
    operations after this delay. If no master code is entered during the 20  
    seconds delay, the lock will enter a 15 minute wait period assuming the  
    Master Code is unknown.
B)  User does not know the Master code:
  1.  Insert mechanical override key, turn counterclockwise and hold so that  
    lock is in open position (cylindrical latch is retracted). Within 5 sec- 
    onds, press # and release the key (latch). 
  2.  You have up to 5 seconds to push ‘#’ and release the override key. If  
    5-second timeout is reached without pressing ‘#’, the lock continues  
    its normal operation. As soon as the ‘#’ is pressed, the lock exits the  
    current state. If timeout is reached or if any other key is pressed     
    after the ‘#’ was pressed, the lock exits the sequence and stays in  
    access state. If ‘#’ is pushed and reset button is release within 
    5-second period, the lock goes in Reset Sequence State and the lock  
    displays the ‘Reset Sequence In Progress message by flashing Green    
    and Red LED alternatively once every second. 
  3.  In this state, users have a 20-second period to enter the Master Code  
    to perform a hard reset. When the user does not know the master  
    code, the user must not enter anything during that 20 seconds delay.  
    The Reset sequence in progress message will be displayed on the  
  LEDs.
  4.  When the 20 seconds delay will be exhausted, a 15 minutes wait period  
    will begin. During that state, any operation on the lock will be ignored  
    (green LED will not blink when pressing keys) and the Green and Red  
    LED will blink once a minute.
  5.  After the 15 minutes delay has exhausted, the Reset sequence in  
    progress message will be displayed on the LEDs again for 20 seconds.  
    During this period, the user must enter the 1-2-3-4-5-6-7-8-# sequence  
    and the lock will reset. If the user fails to do so, the sequence will     
    abort and the lock will resume normal operation.