7
2. You have up to 5 seconds to push ‘#’ and release the override key. If
5-second timeout is reached without pressing ‘#’, the lock continues
its normal operation. As soon as the ‘#’ is pressed, the lock exits the
current state. If timeout is reached or if any other key is pressed after
the ‘#’ was pressed, the lock exits the sequence and stays in access
state. If ‘#’ is pushed and reset button is released within 5-second
period, the lock goes in Reset Sequence State and the lock displays
the ‘Reset Sequence In Progress’ message by flashing Green and Red
LED alternatively once every second.
3. In this state, users have a 20-second period to enter the Master Code
to perform a hard reset. If a bad Master Code is keyed-in, the lock exits
the Reset Sequence State and goes back in access state. If the correct
Master Code is entered within 20 seconds, the lock performs a hard
reset and goes back in unprogrammed state. When an incorrect Master
Code is entered, the Tamper Count decrements. After 4 unsuccessful
attempts to Reset the lock with a bad Master code, the lock goes in
the Tamper Shutdown state for 30 seconds. It will resume normal
operations after this delay. If no master code is entered during the 20
seconds delay, the lock will enter a 15 minute wait period assuming the
Master Code is unknown.
B) User does not know the Master code:
1. Insert mechanical override key, turn counterclockwise and hold so that
lock is in open position (cylindrical latch is retracted). Within 5 sec-
onds, press # and release the key (latch).
2. You have up to 5 seconds to push ‘#’ and release the override key. If
5-second timeout is reached without pressing ‘#’, the lock continues
its normal operation. As soon as the ‘#’ is pressed, the lock exits the
current state. If timeout is reached or if any other key is pressed
after the ‘#’ was pressed, the lock exits the sequence and stays in
access state. If ‘#’ is pushed and reset button is release within
5-second period, the lock goes in Reset Sequence State and the lock
displays the ‘Reset Sequence In Progress message by flashing Green
and Red LED alternatively once every second.
3. In this state, users have a 20-second period to enter the Master Code
to perform a hard reset. When the user does not know the master
code, the user must not enter anything during that 20 seconds delay.
The Reset sequence in progress message will be displayed on the
LEDs.
4. When the 20 seconds delay will be exhausted, a 15 minutes wait period
will begin. During that state, any operation on the lock will be ignored
(green LED will not blink when pressing keys) and the Green and Red
LED will blink once a minute.
5. After the 15 minutes delay has exhausted, the Reset sequence in
progress message will be displayed on the LEDs again for 20 seconds.
During this period, the user must enter the 1-2-3-4-5-6-7-8-# sequence
and the lock will reset. If the user fails to do so, the sequence will
abort and the lock will resume normal operation.