3.5.6 flowI 2103 Brazil
Type number
Nom.
flow
Qn
Min.
flow
Qmin
Max
flow
Qmax
Dynamic
range
Qmax/
Qmin
Min.
cut-
off
Max
cut-off
**)
Pressure
loss
p at Qn
Connection
on meter
Length
Non-
return
valve
Strainer
mounted
m
3
/h
l/h
m
3
/h
l/h
m
3
/h
bar
mm
02C-YY-C0U-8XX
1.5
15
3
200
2
4.6
0.17
G1B
115
No
Yes
02C-YY-C0E-8XX
1.5
15
3
200
2
4.6
0.17
G1B
190
Yes
Yes
02C-YY-C0L-8XX
2.5
25
5
200
3.2
8.5
0.18
G1B
130
Yes
Yes
02C-YY-C0N-8XX
2.5
25
5
200
3.2
8.5
0.18
G1B
190
Yes
Yes
Only available as cold water meter
Qn = 1.5 m³/h ~ (Q3 = 2.5 m³/h)
2.5 m³/h ~ (Q3 = 4.0 m³/h)
YY= 80 = 923 MHz, Mode C1
YY= 90 = 434 MHz Mode C1
8XX= Country Code/time zone (8 = cold water meter)
8BB = Brasilia
8BA = Amazon
8BF = Fernando

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kamstrup MULTICAL 21 and is the answer not in the manual?

Kamstrup MULTICAL 21 Specifications

General IconGeneral
BrandKamstrup
ModelMULTICAL 21
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals