15KANE 458s MANUAL
MAIN MENU SUB MENU OPTIONS/COMMENTS
PRESSURE
FILTER
O F F = n o r m a l r e s p o n s e .
ON = slower (damped) response
RESOLUTION
LOW = e.g. 0.01mbar resolution.
HIGH = displays to an extra decimal place
UNITS
mbar, Pa, PSI, mmHg, hPa, inH2O,
mmH20, kPa, psi
TIME
LET BY = Set duration of let-by test in
minutes. Default = 1 minute
PRINTER
STABIL’N = Set duration of stabilisation in
minutes. Default = 1 minute
PASS KEY
TIGHTN’S = Set duration of tightness test
in minutes. Default = 2 minute
BACK
MAIN MENU SUB MENU OPTIONS/COMMENTS
UNITS
FUEL TYPE
NAT GAS, TOWN GAS, COKE GAS,
PROPANE, BUTANE, LPG, LIGHT OIL,
BIO OIL, WOOD PELLETS, BIO GAS,
USER FUEL 1 TO 5
FUEL ORIGIN
UK, FRANCE, SPAIN, N AMERICA,
BELGIUM, NETHERLAND
EFFICIENCY GROSS, NET, GROSS COND, NET COND
PRESSURE SEE NEXT TABLE BELOW
GAS
PPM, PPM(N), MG/M3, MG/M3(N), MG/
KWH, MG/KWH(N)
TEMP C , F
02 REF
UP/DOWN TO SET VALUE
(3% DEFAULT)
NOX CALC
UP/DOWN TO SET VALUE
(5% DEFAULT)
BACK