30 KANE 458s MANUAL
Calculations
Oxygen 0 - 21% 0.1% ±0.3% Volume
CO/CO2 Ratio 0 - 0.9999 0.0001 ±5% of reading
Eciency (Net or Gross) 0 - 99.9% 0.1% ±1% of reading
Eciency High (C) 0 - 119.9% 0.1% ±1% of reading
Excess Air 0 - 119.9% 0.1% ±0.2% of reading
Pressure (Dierential) ±80mbar 0.1mbar ±0.5% FSD
Pre-programmed Fuels
UK, USA & France
Natural Gas, Propane, Butane, LPG, Light Oil, Digester Gas, Wood
Pellets Heavy Oil
European
Natural Gas, Light Oil, Bio Oil, Coke, LPG, Wood, Town Gas, Butane
& Propane
Battery Life >8 hours (continuous with pump on)
Certication
The KANE458s is independently tested and certied to EN 50379,
Parts 1-3 in accordance to 1st German Federal Emission Control
Ordinance (Bim5chV)
SPECIFICATIONS
PARAMETER RANGE RESOLUTION ACCURACY
Temperature Measurement
Flue Temperature 0 - 600°C 0.1°C ±0.5°C
Inlet temperature
(Internal Sensor)
0 50°C 0.1°C ±1°C
Inlet temperature
(External Sensor)
0 - 600°C 0.1°C ±0.5°C
Flue Gas Measurement
Carbon Monoxide 0 - 2000ppm 1ppm
±3ppm or ±5% of reading
(whichever is greater)
Carbon Dioxide 0 - 20% 0.1% ±0.3% Volume
Oxygen (If tted) 0 - 21% 0.1% ±0.3% Volume
Nitric Oxide (If tted) 0 - 600ppm 1ppm
±5ppm or ±5% of reading
(whichever is greater)