Integration Interface
The KT-1 supports alarm panel interfacing with the appropriate connections made
between zone inputs, relay outputs and the alarm system panel. The KT-1-PCB ver-
sion also supports integration interfacing using RS-232 for fire alarm panel and intru-
sion integrations.
Note: RS-232 interface communication with fire alarm panel has not been eval-
uated by UL.
Automatic Port Detection
The KT-1 automatically detects the site communication speed set by EntraPass as
well as the communication port which can be IP (ETHERNET) or RS-485 (COM1).
Downloadable Firmware
The firmware program can be downloaded from any EntraPass workstation to the
KT-1. It is stored in the controller’s flash memory, and is upgraded without having to
change any parts.
Trouble and Reporting
The KT-1 continuously monitors its power and reports low and critical power issues.
Power outputs are monitored and electronically protected against short-circuits
and surges. Locking devices are also monitored for short and open circuits.
©Copyright, 2016, all rights reserved
16

Table of Contents

Other manuals for Kantech KT-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kantech KT-1 and is the answer not in the manual?

Kantech KT-1 Specifications

General IconGeneral
CommunicationRS-485
Max. Number of Doors1
TypeDoor Controller
Power Supply12 VDC
Reader TechnologyWiegand
Operating Voltage12 VDC

Related product manuals