Compliance Specifications
UL
When KT-1 is enclosed in the metal cabinet model KT-1-CAB and powered by the power supply model
KTPS4085 in conjunction with the external adapter PTC1640UG the following performance levels are
defined for the access control unit as per UL294:
Destructive attack: Level I (no attack test)
Line Security: Level II (Standard line security, RS-485 or Ethernet) and Level III (encrypted line security
128 bit, Ethernet only)
Endurance: level IV (100,000 cycles)
Standby power: Level 1 (when no standby power is provided)and level IV (4 hours, when using KT-
PS485)
Note: If KT-1 is used in a single gang configuration, powered by an external, separately listed power sup-
ply or PoE/PoE+ switch the performance levels remain the same with the exception of the standby time
that will be rated Level I (no secondary power source).
To comply with UL listings, the following requirements must be met:
Installation locations and wiring methods shall be in accordance with the National Electrical Code,
ANSI/NFPA 70. Do not connect to a receptacle controlled by a switch.
Use of a UL listed computer.
Use of UL listed readers (Wiegand 26 and 34 bits, stripe 26 and 34 bits, XSF 39 bits have been tested
and found to comply).
Kantech XSF 39 bits have been tested and found to comply.
Use of a UL recognized tamper switch on every housing cabinet for the KT-1 One-Door Controller.
Do not use the SmartLink option.
Do not use a 230 VAC transformer (not UL listed).
Use only UL listed cables.
Use only UL listed adaptors.
Use only a UL listed power supply such as Kantech part number KT-PS4085 (available through
Kantech distributors or dealers, please refer to the Technical Support contact information at the
beginning of this guide to obtain the specific transformer).
The KT-1-EU has not been validated as a UL Listed system.
The PTC1640UG and 12V/7Ah battery are used for 4 hours of standby power.
Note: All circuits are power limited with the exception of battery connection. Separation of 3/4" shall be
maintained between power limited and non-power limited wiring.
Note: Replace Battery with Pansonic or Energizer Part No. CR2032 Only. Use of another battery may
present a risk of fire or explosion.
UL 294 Compliance Notice
Use only UL 294 or UL 1076 listed power supply.
Connect Kantech part number KT-ACPW-LED status indicator to the AC terminals of the KT-PS4085.
Use Kantech part number KT-BATT-12 battery.
Note: Using a 12V/7Ah battery, backup battery provides a minimum of 4 hours stanby time.
© Copyright, 2016, all rights reserved

Table of Contents

Other manuals for Kantech KT-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kantech KT-1 and is the answer not in the manual?

Kantech KT-1 Specifications

General IconGeneral
CommunicationRS-485
Max. Number of Doors1
TypeDoor Controller
Power Supply12 VDC
Reader TechnologyWiegand
Operating Voltage12 VDC

Related product manuals