Forced Default Static
Same as 'Soft Reset' condition, except IP address is forced to the default static IP:
192.168.1.2 Subnet mask: 255.255.255.0.
The LED flashing pattern will remain on Force default static flashing beat (3
reversed pulses), until controller is reset to another mode.
Factory Default DHCP
All controller's memory is settled to default values.
Internal event buffer is cleared.
Controller generates the message 'Controller Factory Default Reset'.
The flashing beat of vital LED is Reversed Flash” continuous beat.
Internal RTC and clock are settled to the default time and date values January 1st
2014, 00:00:00, Wednesday.
Controller waits for valid communication from EntraPass to be received on any
effective comm port (ETH, RS-485) which will configure Controller Master Mode.
Power LED Status Indicator
There are two power LED status indicators, one green and one yellow. The colors
indicate when the primary power supply is present. The specific LED which illu-
minates is dependent upon the power source.
WARNING: DO NOT LOOK DIRECTLY AT LED WITH UNSHIELDED
EYES, OR DAMAGE TO RETINA MAY OCCUR.
Default Initialization
The KT-1 default initialization or Factory Default DHCP is done at Kantech. The fol-
lowing steps should be followed only if:
You want to configure the KT-1 with the KT-Finder. (Refer to the section on con-
figuring the KT-Finder, in this guide).
The KT-1 was communicating via a VC-485 or a USB-485 interface and you want
to communicate via the ethernet port.
You are using a KT-1 from another site and there is no communication.
© Copyright, 2016, all rights reserved
41

Table of Contents

Other manuals for Kantech KT-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kantech KT-1 and is the answer not in the manual?

Kantech KT-1 Specifications

General IconGeneral
CommunicationRS-485
Max. Number of Doors1
TypeDoor Controller
Power Supply12 VDC
Reader TechnologyWiegand
Operating Voltage12 VDC

Related product manuals