8.3. Kempact 253MV, 323MV
8.3.1. Primary rectifier, V31
Primary side primary rectifier diodes can be measured one at the time
Diodes must be measured both forward bias and reverse bias condition to make sure they are fine
Check the diodes using the multimeter diode function to measure their threshold voltage 0,3…0,6 V
Measurings :
1) Negative test pole to rectifier pole (1, black), positive test pole to rectifiers poles (1, red) one at time
Result: 0,3…0,6diodes Ok.
2) Positive test pole to rectifier pole (3, red), negative test pole to rectifier poles (2, black) one at the time
Result: no valuediodes Ok
3) Positive test pole to rectifier pole (2, red), negative test pole rectifier poles (2, black)one at the time
Result: 0,3…0,6diodes Ok
4) Negative test pole to rectifier pole (3, black), positive test pole to rectifier poles (2, red) one at the time
Result: no valuediodes Ok