3.3.9 Use of gas test
If you press the gas test button, gas will begin to ow without any starting power source or
wire feed. Gas ow can be measured by using an external measuring device.
Cut o the gas ow by pressing the same button again, or the gun trigger. If the trigger is not
pressed again, the gas ow will end within 20 seconds.
The display will show “GAS” and the time.
3.3.10 Testing wire feed
The wire feed switch will start the wire feed motor without opening the gas valve. The power
source will start up, but without providing welding power. The wire feed range will be 5m/min
but can be adjusted as desired.
3.3.11 Memory channels, MEMORY
The pulse panel has 100 channels for dierent welding options. Memory channels can be
chosen on the lower part of the panel using the memory block. Both welding values and
functions can be saved. Do the following:
1. Press
twice if needed and and the SET light will start blinking if the channel is
not in use, while the light will stay on if the channel is in use.
2. Select the memory channel you want by pressing CH button
3. Make settings and save by pressing SAVE button.
4. Press
twice. ON light turns on.
5. Start welding and set the values.
To change the values, the light must be switched from the ON to SET and then you can choose
the parameters, pressing the SAVE button afterwards. It is also possible to save the used
parameters by pressing SET when memory function is OFF (no lights). The channel can be
emptied by pressing
and SET button in SET simultaneously.
Using saved settings
1. Press
button.
2. Select the memory channel by pressing the CH button.
3. Start welding.
Memory channels in control device
Select memory channels by pressing the CH REMOTE button simultaneously and the gun
control light will start to blink. Use the saved values through the gun’s remote control.
You can use ve channels.