page 80 of 94© KEYMILE December 2015 EN/LZTBU 372 129/1 RC
94
User Interface Reference
8.2.5 AP: / unit-x, Status
8.2.5.1 AP: / unit-x, Status - General
8.2.5.2 AP: / unit-x, Status - Maintenance
PWRSVE Battery Power Saving Equipment
Alarm
Critical Power saving is active on the unit, i.e. it
is kept in the “reset” state during battery
power backup.
Table 43: AP: / unit-x, Fault Management (continued)
ID Fault Cause Event Type Traffic
Affecting
Default
Severity
Description
Table 44: AP: / unit-x, Status - General
Operation Name Parameter Name Range Description / Details
Temperature Board Temperature -50 … 150 °C
Indicates the actual unit temperature in degree
Celsius.
Table 45: AP: / unit-x, Status - Maintenance
Operation Name Parameter Name Range Description / Details
Unit Admin Status State
a
Some Ports Unlocked
At least one port is unlocked.
All Ports Locked
All ports on the unit are in the locked state.
Shutdown All Ports
b
Shutdown all enabled user ports. The user ports
are blocked (locked state) as soon as the sub-
scriber state “idle” has been detected.
Lock All Ports
b
Lock all enabled user ports. The user ports are
blocked (locked state) immediately after confir-
mation of the warning message.