SCPI Command *RST Settings
SENSe:SWEep:TINTerval 5.12E–6
SENSe:WINDow RECTangular
STEP:TOUTput OFF
TRIGger:ACQuire:CURRent 0
TRIGger:ACQuire:CURRent:SLOPe POSitive
TRIGger:ACQuire:SOURce BUS
TRIGger:ACQuire:TOUTput OFF
TRIGger:ACQuire:VOLTage 0
TRIGger:ACQuire:VOLTage:SLOPe POSitive
TRIGger:ARB:SOURce BUS
TRIGger:TRANsient:SOURce BUS
VOLTage 0.1% of rating
VOLTage:LIMit 1% of rating
VOLTage:MODE FIXed
VOLTage:PROTection 120% of rating
VOLTage:RESistance 0
VOLTage:RESistance:STATe OFF
VOLTage:SLEW MAX
VOLTage:SLEW:MAXimum ON
VOLTage:TRIGgered 0.1% of rating
Non-Volatile Settings
The following table shows the as-shipped settings of the non-volatile parameters. These are not
affected by power cycling or *RST.
SCPI as-shipped settings
CALibrate:DATE empty string
CALibrate:PASSword 0
DIGital:PIN<all>:FUNCtion DINput
DIGital:PIN<all>:POLarity POSitive