EasyManua.ls Logo

Keysight N3300A - Specifications

Keysight N3300A
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
71
A
Specifications
Table A-1 lists the specifications for the different load models. Specifications indicate warranted performance in
the 25°C ±5°C region of the operating temperature range. Specifications apply to normal and transient modes
unless otherwise noted.
Table A-1. Specifications
N3302A
N3303A
N3304A
N3305A
N3306A
N3307A
Input Ratings
Current
0 - 30 A
0 - 10 A
0 - 60 A
0 - 60 A
0 - 120 A
0 - 30 A
Voltage
0 - 60 V
0 - 240 V
0 - 60 V
0 - 150V
0 - 60V
0 - 150V
Maximum Power @ 40°C
1
150 W
250 W
300 W
500 W
600 W
250 W
Input Characteristic
Voltage
Max Power Contour
0
full
scale
OPERATING CONTOUR
0
DERATED CURRENT DETAIL
1
2
3
all specifications apply
slew rate limitations apply
Current Current
Voltage
(see Table A-2)
full
scale
full
scale
Specified Current @
Low Voltage Operation
2.0 V
30 A
10 A
60 A
60 A
120 A
30 A
1.5 V
22.5 A
7.5 A
45 A
45 A
90 A
22.5 A
1.0 V
15 A
5 A
30 A
30 A
60 A
15 A
0.5 V
7.5 A
2.5 A
15 A
15 A
30 A
7.5 A
0 V
0 A
0 A
0 A
0 A
0 A
0 A
1
Maximum continuous power available is derated linearly from 100% of maximum at 40°C, to 75% of maximum at 55°C.
Typical Minimum Operating Voltage @ Full Scale Current
N3302A
N3303A
N3304A
N3305A
N3306A
N3307A
Table A-1 states that maximum
current is available down to 2
volts. Typically, under normal
operating conditions, the load
can sink the maximum current
down to the following voltages:
1.2 V 1.2 V 1.2 V 1.4 V 1.4 V 1.4 V