Quick Reference - 1
15
Front Panel Menus - At a Glance
ADDRESS 5
Sets the GPIB Address
INTF GPIB
Selects an interface (GPIB or RS232)
BAUDRATE 300
Selects baud rate (300, 600, 1200, 2400, 4800, 9600) *
PARITY NONE
Selects message parity (NONE, EVEN, ODD, MARK, SPACE) *
FLOW NONE
Selects flow control (XON-XOFF, RTS-CTS, DTR-DSR, NONE) *
*RCL 0
Recalls the instrument state
*RST
Resets the instrument to its power-on state
*SAV 0
Saves the present instrument state
ERROR 0
Displays the number of errors in the SCPI error queue
CHANNEL 1
Allows selection of channel to be controlled by the front panel
S:PNT
Defines the number of data points in the measurement
S:TIN
Sets the digitizer sample spacing
S:WIN
Sets the measurement window function (RECT, HANN)
S:OFF
Defines the data offset in the measurement
S:C:RNG
Selects the current measurement range
S:V:RNG
Selects the voltage measurement range
FUNC
Sets the regulation mode (CURR, RES, VOLT)
FNC:MODE
Selects what controls regulating mode (FIX, LIST)
INP:SHOR
Enable/disables the input short (OFF/ON)
OC -- -- --
General protection status (overcurrent fault shown)
RRV --- --
Voltage protection status (remote reverse voltage fault shown)
XXXX XXXX
Displays the input voltage and current
XXXX V MAX
Displays the maximum voltage
XXXX V MIN
Displays the minimum voltage
XXXX V RMS
Displays the rms voltage
XXXX A MAX
Displays the maximum current
XXXX A MIN
Displays the minimum current
XXXX A RMS
Displays the rms current
XXXX WATTS
Displays the wattage
XXXX W MAX
Displays the maximum wattage
XXXX W MIN
Displays the minimum wattage
CURR
Sets the input current
C:MODE
Sets the current mode (FIXED, LIST)
C:RANG
Sets the input current range
C:SLEW
Sets current slew rate
C:SLW:N
Sets current slew rate for negative transitions
C:SLW:P
Sets current slew rate for positive transitions
C:TLEV
Sets the transient input current
C:TRIG
Sets the triggered input current
RES
Sets the input resistance
R:MODE
Sets the resistance mode (FIXED, LIST)
R:RANG
Sets the input resistance range
R:SLEW
Sets resistance slew rate
R:SLW:N
Sets resistance slew rate for negative transitions
R:SLW:P
Sets resistance slew rate for positive transitions
R:TLEV
Sets the transient input resistance
R:TRIG
Sets the triggered input resistance
*Only applicable for use with RS-232
Address
Recall
Save
Shift
Error
Shift
Channel
Shift
Sense
Shift
Func
Protect
Current
Res
Meter